Installing the chassis rails, Installing the rack rails – SUPER MICRO Computer 5010E User Manual

Page 22

Advertising
background image

2-4

S

UPER

S

ERVER

5010H/5010E

Manual

Installing the Chassis Rails:

Position the fixed chassis rail sections you just removed along the side of

the 5010H/5010E chassis making sure the five screw holes line up.

Note

that these two rails are left/right specific. Screw the rail securely to the

side of the chassis (see Figure 2-2). Repeat this procedure for the other

rail on the other side of the chassis. You will also need to attach the rail

brackets when installing into a telco rack.

Locking Tabs: As you have seen, both chassis rails have a locking tab,

which serves two functions. The first is to lock the server into place

when installed and pushed fully into the rack, which is its normal position.

Secondly, these tabs also lock the server in place when fully extended

from the rack. This prevents the server from coming completely out of

the rack when you pull it out for servicing.

Figure 2-2. Installing Chassis Rails

Installing the Rack Rails:

Determine where you want to place the SuperServer 5010H/5010E in the

rack. (See Rack and Server Precautions in Section 2-3.) Position the fixed

rack rail/sliding rail guide assemblies at the desired location in the rack,

keeping the sliding rail guide facing the inside of the rack. Screw the

Advertising