Sanyo DC Inverter Split System XHS1271 User Manual

Page 122

Advertising
background image

4

Fig. 9

Fig. 10

Fig. 11

ON/OFF
operation button

1 HR.TIMER
button

NIGHT SETBACK
button

ACL (Reset)
button

SENSOR button

OPERATION lamp

TIMER lamp

HIGH POWER lamp

REMOTE CONTROL receiver

OPERATION button

How to Test Run the Air Conditioner

After turning on the power of the air conditioner, use the

remote controller and follow the steps below to conduct

the test run.

(1) Set the remote controller in Test Run mode. (Fig. 9)

a)Press and hold the NIGHT SETBACK button and

the 1HR. TIMER button.

b)Then press and hold the ACL (Reset) button with

a pointed object such as the tip of a pen. After 5

seconds, release the ACL button first.

c) Then release the NIGHT SETBACK and 1HR.

TIMER buttons.

d)

appears and “oP-1” blinking in the remote con-

troller clock display area. (Fig. 10)

(2) Start Cooling mode test run by pressing the ON/OFF

operation button of the remote controller. (Fig. 9)

• This starts the fan producing uncooled forced air

with the 3 indicator lamps (OPERATION lamp,

TIMER lamp, and HIGH POWER lamp) on the

main unit blinking. (Fig. 11)

• After 3 minutes, the system shifts into cooling

operation, and cool air will start to be felt. Cooling

mode test run is unaffected by the room tempera-

ture.

(3) Press the ON/OFF operation button of the remote

controller again to stop the test run. (Fig. 9)

(4) Finally press the ACL (Reset) button of the remote

controller to release it from Test Run mode to return

to normal mode. (Fig. 9)

• “

” and “oP-1” will disappear from the remote

controller clock display area.

Troubleshooting:

In the event that the green OPERATION lamp is blinking

upon powering up the system, an error condition exists.

In this case, refer to the self-diagnostics procedure

which can be seen by opening the air-intake grille.

After the test run is completed, be sure to press the

ACL (Reset) button to return to normal mode. The air

conditioner will not operate correctly if this is not done.

IMPORTANT

NOTE

08-230 STK-RCS-7TWSU 9/29/08 10:23 AM Page 4