3-7. remove the heat exchanger sensor, 3-8. remove the drain pump and float switch – Sanyo DC Inverter Split System XHS1271 User Manual

Page 44

Advertising
background image

7-3-7. Remove the heat exchanger sensor.

(1) Remove the heat exchanger sensor from the sensor holder. (Fig. 19)

7-3-8. Remove the drain pump and float switch.

(1) Remove the 2 screws (Fig. 20)
(2) Loosen the clamp and disconnect the drain hose from the drain pump. (Fig. 20)
(3) Remove the drain pump from the main body upper section. (Fig. 20)
(4) Remove a nut and remove the float switch. (Fig. 21)

Heat exchanger sensor

Fig.20

Fig.21

Fig.19

Holder

Drain pump

Screw

Clamp

Float switch

Nut

Drain hose

44

Advertising