Insulation of refrigerant tubing – Sanyo DC Inverter Split System XHS1271 User Manual

Page 21

Advertising
background image

Compressor

4-way

valve

Accumulator

High pressure

switch

Wide tube

service

valve

Wide tube

Narrow

tube

service

valve

Narrow tube

Heat exchanger

Muffler

Capillary

tube for

split flow

Cooling cycle

(Defrosting cycle)

Heating cycle

Indoor unit

Outdoor unit

Electric

expansion

valve

Strainer

M

O.D.

1/2"

(12.7mm)

O.D.

1/4"

(6.35 mm)

H.P.

Indoor Unit

XHS1872 & PNR-XS1872

Outdoor Unit CH1872

Insulation of Refrigerant Tubing

Because capillary tubing is used in the outdoor unit, both the

wide and narrow tubes of this air conditioner become cold. To

prevent heat loss and wet floors due to dripping of

condensation, both tubes must be well insulated with a

proper insulation material. The thickness of the insulation

should be a min. 5/16"(8 mm).

After a tube has been insulated,

never try to bend it into a narrow

curve because it can cause the tube

to break or crack.

Wide tube

Thickness:

Min. 5/16"(8 mm)

Insulation

Narrow tube

Thickness:

Min. 5/16"(8 mm)

IMPORTANT

CAUTION

Heat exchanger

Strainer