Adjustment tips and functions

31

̈

Position the transmitter in the area in which it is to be used and switch
it on.

̈

Leave the transmitter switched on and go to your receiver.

̈

On the receiver, change to the “

Soundcheck

” standard display.

̈

Go to your transmitter.

̈

With the transmitter, walk up and down the area in which it is to be
used.

̈

Then leave the transmitter there and do

not

switch it off.

During the soundcheck, the receiver records the RF level and the AF level.
The recording result is displayed on the “

Soundcheck

” standard display:

If no transmitter is being received or if the signal is below the
squelch threshold level, “

MUTE

” appears on the display panel (see

“If a problem occurs ...” on page 47).