I/o configuration, Input select, I/o mode – SIGMA EQ Station User Manual

Page 31: Ada i/o settings, Setup page

Advertising
background image

29

CONTROL SECTION

The Setup page contains functionality parameters and
device configuration. These settings will normally be
"set-and-forget" functions, not meant to change very
often.

I/O Configuration

The Digital I/O options and parameters described in the
following section will only be available if the optional
Digital AES/EBU card is installed

Input Select

For each set of Inputs you may select whether the EQ
Station should process the analog or digital signal present
on the respective Inputs.
This is set via the Input Select page.

4 channel version
Digital

Analog

Input 1+2

1+2

Input 3+4

3+4

Input 5+6
Input 7+8

8 channel version
Digital

Analog

Input 1+2

1+2

Input 3+4

3+4

Input 5+6

5+6

Input 7+8

7+8

Outputs
All available Outputs, both analog and digital are
open all the time.

Options that are unavailable due to the configuration
of your frame are ghosted in the EQ station menus.

I/O Mode

Channel 1-8 Thru mode or Mixer/Matrix mode
The 1-8 Thru mode is made for applications where multiple
mono- or stereo-paired channels are required, e.g. for
monitor mix setups.
In Mix/Matrix mode it is possible to create a stereo mix of
several Input sources then distribute the stereo mix to
several Outputs.

See Local page section for further description.

ADA I/O Settings

Equal settings on the Max AD In Level and Max Out Level
parameters gives unity gain through the unit.

Max AD In Level:
Range: 3 to 30dBu in 3dB steps
Input sensitivity that can be set on each input pair. The
expected dynamic content of the signal to be processed
should be determined and the Max AD In Level parameter
should be set accordingly to ensure sufficient headroom.

Setup page

Advertising