Utility page, Midi - ui channel select, Scene recall – SIGMA EQ Station User Manual

Page 35

Advertising
background image

33

UTILITY PAGE

The Utility page holds a variety of operation and
performance features.

MIDI - UI Channel Select

These parameters concern external channel control from
e.g. a mixer with MIDI. When selecting a channel on the
mixer to edit, you may want to see the same channel on
the EQ Station. This is possible by setting the following
parameters.

MIDI Channel:
Range: 1-16 or Omni
Sets the MIDI channel for UI Channel select.

Prog. Change
Off - The EQ Station does not respond to received MIDI
Program Changes on the selected channel.

In - Channels 1-64 are selected when program changes
1-64 on the selected MIDI channel is received.

Out - When selecting a channel on the EQ Station the EQ
Station will send out a Program Change message
simultaneously on the specified channel.

In+Out - With both In and Out selected the Channel to view
or edit on the mixer and EQ Station can be set from both
the mixer and from the EQ Station.

Control Change
The channel appearence of the EQ Station can also be
controll via MIDI CC’s.

Off - No response to MIDI CC values and no MIDI CC
values are sent.

In - Channel select on the EQ Station can be controlled
externally by a received MIDI CC value.
Per default values 0-63 on the set CC Number (0-119)
selects channels 1-64. However, the offset parameter can
be used to interface with devices sending values from
starting from 1.

Out - When channels are selected locally a MIDI CC value
on the set controller will be sent on MIDI Out. Connected
devices set up to receive these messages will respond.

In+Out - See above. The described features on both In and
Out applies.

Control Change Offset
Options: 0 to 63 or 1 to 64
Some devices send values starting from “0” and some from
“1”. The object is to select channels 1-64 in the UI. If your
controlling device displays control change values in the
display, these values typically start from 0. To be able to
associate those values directly with an EQS channel
number, you can select the "1 to 64" option, in which case
a control change value of 1 will select the first EQS
channel. Default setting is “0 to 63”.

CC Number:
Range: 0-119
Sets the CC number for UI channel select.

Scene Recall

The following parameters set conditions for external scene
recall.

MIDI Channel
Range: 1-16 or Omni
Defines on which MIDI channel the EQ station can receive
and send MIDI program change messages for a Scene
recall.

Prog. Change
Off - No response to MIDI program changes and no MIDI
program changes are sent at Scene recall.

In - Scenes can be recalled form an external MIDI device
or another EQ Station on the selected MIDI channel and
according to the MIDI map.

Out - When a Scene is recall locally a MIDI program
change is sent on the selected MIDI channel.

In+Out - See above. The described features on both In and
Out applies.

Map From - Map to
An incoming MIDI Pr. Change message from 1 to 128 can
be mapped to recall any Scene preset.

Advertising