Programmable vfo, Changing frequency step size – Kenwood TH-D7E User Manual

Page 52

Advertising
background image

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

46

PROGRAMMABLE VFO

If you always check frequencies within a certain range,
set upper and lower limits for frequencies that are
selectable using the Tuning control or [UP]/ [DWN]. For
example, if you select 145 MHz for the lower limit and
146 MHz for the upper limit, the tunable range will be
from 145.000 MHz to 146.995 MHz.

1 Press [A/B] to select band A or B.

• If necessary, press [F], [A/B] to recall the sub-band.

2 Press [VFO].

3 Press [F], [7] to select “F–7 (PROGRAM VFO)”.

• The current lower frequency limit blinks.

4 Press [UP]/ [DWN] to select the desired lower

frequency limit.

5 Press [OK].

• The current upper frequency limit blinks.

6 Press [UP]/ [DWN] to select the desired upper

frequency limit.

7 Press [OK].

Note:

You cannot program the 100 kHz and subsequent digits.

The exact 100 kHz and subsequent digits of the upper limit depend
on the frequency step size selected.

STA CON

PACKET96BCONDUP

9

7

5

CHANGING FREQUENCY STEP SIZE

Choosing the correct step size is essential in order to
select your exact receive frequency using the Tuning
control or [UP]/ [DWN]. The default step size on the
VHF band is 5 kHz (TH-D7A) or 12.5 kHz (TH-D7E).
The default on the UHF band is 25 kHz no matter which
market version.

1 Press [A/B] to select band A or B.

• If necessary, press [F], [A/B] to recall the sub-band.

2 Press [F], [8] to select “F–8 (STEP)”.

3 Press [UP]/ [DWN] to select the desired step size.

• The selectable step sizes are 5, 6.25, 10, 12.5, 15, 20,

25, 30, 50, and 100 kHz.

4 Press [OK] to complete the setting.

Note: Changing between step sizes may correct the displayed
frequency. For example, if 144.995 MHz is displayed with a 5 kHz step
size selected, changing to a 12.5 kHz step size corrects the displayed
frequency to 144.9875 MHz.

STA CON

PACKET96BCONDUP

9

7

5

STA CON

PACKET96BCONDUP

9

7

5

TH-D7 E 45 Auxiliary Functions

98.12.4, 0:12 PM

46

Advertising