Kohler Marine Generator Sets 11EFOZ/13EOZ User Manual

Page 25

Advertising
background image

TP-6069 6/03

15

Section 4 Exhaust System

Waterline

7

14

13

12

15

10

9

8

18

11

19

6

17

4

5

20

16

1

2

3

21

TP-5856-4

1. Mounting base
2. Retaining cap
3. Reed valve assembly
4. Maximum silencer vertical lift of 1.2 m (4 ft.)
5. Exhaust mixer elbow distance above waterline; if less than

23 cm (9 in.), a siphon break is required

6. Minimum siphon break distance above waterline of 30.5 cm

(1 ft.)

7. Siphon break
8. Exhaust mixer elbow
9. Heat exchanger (locations vary by model)

10. Coolant recovery tank (located on the unit on some models)

11. Indicates the coolant recovery tank is at the same height as the

heat exchanger

12. Seawater strainer
13. Seacock
14. Intake strainer

15. Engine-driven seawater pump
16. Minimum exhaust hose pitch of 1.3 cm per 30.5 cm (0.5 in. per ft.)
17. Maximum distance between silencer and exhaust mixer elbow

of 3 m (10 ft.)

18. Silencer (customer-supplied)
19. Minimum exhaust hose pitch of 1.3 cm per 30.5 cm

(0.5 in. per ft.)

20. Minimum exhaust outlet distance above waterline of 10 cm

(4 in.)

21. Exhaust hose (see Figure 4-7 for hose sizes)

Note:

Read the text for complete explanation of dimensions and
other installation considerations.

Note:

Use two hose clamps on each end of all flexible exhaust
hose connections.

Note:

Data applies to both rear- and side-exhaust installations.

Figure 4-6

Typical Mid and Below Waterline Installation

Models without Sound Shield

Models with Sound Shield

Exhaust Hose

Diameter

mm (in.)

3.5/4/6.5/8.5/9EFOZ
4/5/8/10EOZ

4/6.5/8.5/9/11/11.5/13/16/17.5/19/20EFOZ
5/8/10/13/14/15.5/20/23/24EOZ

51 (2.0)

11/11.5/13/16/17.5/19/20/23/27EFOZ
13/14/15.5/20/23/24/28/32EOZ

27EFOZ
32EOZ

76 (3.0)

33EFOZ
40EOZ

33EFOZ
40EOZ

89 (3.5)

40/55/70/80/100/125EFOZ
50/65/80/99/125/150EOZ

40/55/70/80/100/125EFOZ
50/65/80/99/125/150EOZ

102 (4.0)

Figure 4-7

Exhaust Hose Sizes