Appendix c generator set output ratings procedure – Kohler Marine Generator Sets 11EFOZ/13EOZ User Manual
Page 88

TP-6069 6/03
A-4 Appendix
Appendix C Generator Set Output Ratings Procedure
Kohler Co. develops the kilowatt output rating of a Kohler
r
marine generator set based upon the calculations
specified in ISO 3046 and ISO 8528-1. The calculations
correct for environmental variables encountered in a
generator
set
installation.
Figure 1
outlines
the
calculations.
Figure 2 contains examples of how heat
variables affect generator set ratings.
Generator Output
corrected
= Generator Output
observed
x Correction Factor
Output power is expected to be within
±5% of the specified rating when corrected to reference conditions.
Correction factors are determined using the following formulas:
1.
For naturally aspirated compression-ignition engines (power limited by excess air):
C.F. = [1.175 (29.2 / Dry Barometer in. Hg)
1
(Temperature
_F + 460/537)
.75
-- .175]
x Alternator Efficiency
Reference
/ Alternator Efficiency
Observed
2.
For turbocharged compression ignition engines:
C.F. = [1.175 (29.2 / Barometer
Observed
in. Hg)
.7
(Temperature
_F + 460/537)
2
-- .175]
x Alternator Efficiency
Reference
/ Alternator Efficiency
Observed
3.
For turbocharged and intercooled compression ignition engines:
C.F. = [1.175 (29.2 / Barometer
Observed
in. Hg)
.7
(Temperature
_F + 460/537)
1.2
-- .175]
x Alternator Efficiency
Reference
/ Alternator Efficiency
Observed
Reference conditions:
Temperature: 77
_F; Pressure: 29.2 in. Hg dry barometer.
Kohler sound shield increases ambient intake air approx. 12
_F
Approximate derates:
Temperature: approximately 1% per 10
_F (turbocharged engines have a greater derate);
Pressure (altitude): approximately 4% per 1000 ft. (1 in. Hg)
Figure 1 Generator Output
5.5
5.6
5.7
5.8
5.9
6.0
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
75
80
85
90
95
100
105
110
115
120
Temperature (
_F)
77
60 Hz
50 Hz
KEY
Figure 2 Example: 6.5EFOZ/8EOZ kW Derates (ISO 3046/ISO 8258-1)
- Marine Generator Sets 4EFOZ/5EOZ Marine Generator Sets 20EFOZ/24EOZ Marine Generator Sets 40EFOZ/50EOZ Marine Generator Sets 3.5EFOZ/4EOZ Marine Generator Sets 23EFOZ/28EOZ Marine Generator Sets 19EFOZ/23EOZ Marine Generator Sets 11.5EFOZ/14EOZ Marine Generator Sets 16EFOZ/20EOZ Marine Generator Sets 6.5EFOZ/8EOZ Marine Generator Sets 9EFOZ/10EOZ Marine Generator Sets 8.5EFOZ Marine Generator Sets 17.5EFOZ/20EOZ Marine Generator Sets 100EFOZ/125EOZ Marine Generator Sets 80EFOZ/99EOZ Marine Generator Sets 13EFOZ/15.5EOZ Marine Generator Sets 125EFOZ/150EOZ Marine Generator Sets 33EFOZ/40EOZ Marine Generator Sets 27EFOZ/32EOZ Marine Generator Sets 55EFOZ/65EOZ