Section 6 Electrical System

Amps

Max.

Voltage

Number

of Poles

Model(s)

20

250

1

4EFOZ

20

600

3

8.5/11.5EFOZ, 14EOZ

22

250

2

4EFOZ, 5EOZ

25

250

2

5EOZ

250

1

6.5EFOZ

30

250

2

6.5EFOZ

30

600

3

11.5/17.5/20EFOZ,

14/20/24EOZ—3 phase

33

250

2

8EOZ

35

250

1

4EFOZ

35

250

2

8EOZ

250

1

5EOZ

40

600

3

11.5EFOZ,

14/20/24EOZ—3 phase

42

250

1

9EFOZ

42

250

2

9EFOZ, 8/10EOZ

240

1

11/13EFOZ

240

2

11/11.5/17.5EFOZ

50

250

2

9EFOZ, 10EOZ

480

3

20/23/27EFOZ,

20/28/32EOZ—3 phase

55

250

1

5EOZ

240

1

13EFOZ

240

2

11/13EFOZ, 13/14EOZ

60

250

1

6.5EFOZ

600

3

17.5/20EFOZ,

20/24/28/32EOZ—3 phase

240

1

16EFOZ

70

240

2

13/20EFOZ, 15.5EOZ

70

250

1

6.5EFOZ, 8EOZ

600

3

20/24EOZ—3 phase

1

16/19EFOZ

80

240

2

16EFOZ, 20EOZ—1 phase,

20/24EOZ—3 phase

80

250

1

8EOZ

480

3

23EFOZ—3 phase

85

250

1

9EFOZ, 10EOZ

1

19EFOZ

90

240

2

19EFOZ—1 phase

20/23EOZ

480

3

27EFOZ—3 phase

240

2

23EOZ

100

480

3

23/27EFOZ,

28/32EOZ—3 phase

125

600

2

23/27EFOZ, 28EOZ—

1 phase, 27EFOZ—3 phase

125

600

3

23/27EFOZ,

28/32EOZ—3 phase

150

600

2

28/32EOZ—1 phase,

32EOZ— 3 phase

175

600

2

32EOZ—1 phase

Figure 6-2

AC Circuit Breaker Ratings (4--27EFOZ
and 5--32EOZ Models), Listed By Amps

Amps

Max.

Voltage

Number

of Poles

Type

Model(s)

60

600

3

UL/IEC

33EFOZ, 40EOZ

70

600

3

UL/IEC

40EFOZ, 40EOZ

80

480

3

UL/IEC

40EFOZ, 50EOZ

100

480

3

UL/IEC

55EFOZ, 50/65EOZ

100--125

600

3

IEC

33/55EFOZ,

40/65EOZ

100--125

600

3

IEC

70EFOZ, 80EOZ

125

600

3

UL

33/55EFOZ,

40/65EOZ

125

600

3

UL

70EFOZ, 80EOZ

128--160

600

3

IEC

33/40EFOZ,

40/50EOZ

128--160

600

3

IEC

70/80EFOZ,

80/99EOZ

150

600

3

UL

33/40EFOZ,

40/50EOZ

150

600

3

UL

70/80EFOZ,

80/99EOZ

160--400

600

3

UL

70/80/100EFOZ,

80/99/125/150EOZ

160--400

600

3

IEC

70/80/100/125EFOZ,

80/99/125/150EOZ

200

600

3

UL

40/55EFOZ,

50/65EOZ

200

600

3

UL

100EFOZ,

99/125EOZ

200--250

600

3

IEC

40/55EFOZ,

50/65EOZ

200--250

600

3

IEC

70/100/125EFOZ,

80/125/150EOZ

240--600

600

3

UL

125EFOZ,

125/150EOZ

250

600

3

UL

55EFOZ, 65EOZ

250

600

3

UL

70/125EFOZ,

80/125/150EOZ

250--630

600

3

IEC

125EFOZ,

125/150EOZ

Figure 6-3

AC Circuit Breaker Ratings (33--150 kW
Models), Listed By Amps

Accidental starting.
Can cause severe injury or death.

Disconnect the battery cables before
working

on

the

generator

set.

Remove the negative (--) lead first
when

disconnecting

the

battery.

Reconnect the negative (--) lead last
when reconnecting the battery.