C.3. rs-232c/rs-422a protocol, Rs-232c/rs-422a protocol – Kyocera FS1750 User Manual

Page 115

Advertising
background image

C.3. RS-232C/RS-422A Protocol

C-8

C.3.

RS-232C/RS-422A Protocol

A protocol is a set of rules the computer follows in sending data to the printer. The RS-232C/RS-422A param-
eters are stored in battery backed-up memory. They are indicated on the status printout. They can be
changed by the FRPO (firmware reprogram) command described in the Programming Manual. The param-
eters and their identification codes are given below.

H1: Baud rate

The factory setting is 9600 baud.

H2: Data bits

7 or 8, factory-set to 8.

H3: Stop bits

1 or 2, factory-set to 1.

H4: Parity

The factory setting is "None" (0 on the status printout).

H5: Protocol logic

The factory setting is 0.

H6: Buffer nearly-full threshold

This is a percentage from 0 to 99. The factory setting is 90.

Parameter value

Baud rate

12

1200

24

2400

48

4800

96

9600

19

19200

38

38400

57

57600

11

115200

Parameter value

Meaning

0

None

1

Odd

2

Even

3

Ignore

Parameter value

Meaning

0

Combination of 1 and 3 below

1

DTR/DSR, positive logic

2

DTR/DSR, negative logic

3

XON/XOFF

4

ETX/ACK

5

XON/XOFF recognized only as protocol

Advertising
This manual is related to the following products: