DESCRIPTION

WTC 600 LP / MP

Service Handbook 08.2004

Filter Container

Volume per container

103 l

Filling capacities, Mediafilter

Support pebbles 2.0 - 3.15 mm

15 kg

Filter sand 0.4 - 0.8 mm

100 kg

Filter amounts, activated carbon filter

Support pebbles 1 - 2 mm

15 kg

Activated carbon filter F100

32 kg

Water connections

Inlet threaded connection hose nozzle

Outer diameter d25

Drinking water threaded connection hose nozzle

Outer diameter d25

Concentrate threaded connection hose nozzle

Outer diameter d25

Outlet for flushing water

HT pipe d50

Canal connection (supplied by customer)

> DN 50

Hydraulic Data

Maximum allowable flow rate in filteroperation

1,3 m

3

/h

Amount of waste water produced during

2 m³/h, ca. 670 liter per backwashing

backwashing

Allowable Operating Conditions

Maximum pressure

6 bar

Metering Pump

Feed capacity at max. counter-pressure (10 bar)

1 l/h

Metering Container:

Weight with pump

10 kg

Connections

Hose connections (PE) di/do

4/6

Hose connection, ventilation (PVC) di/do

4/6

Float Switch

Minimum hysteresis

300 l

Table 4