APPENDIX

WTC 600 LP / MP

Service Handbook 08.2004

t rinse interval

function:

Time after which a DISCONTINUOUS RINSE
process is started provided that the control
system was during that time in the operating
condition RINSE INTERVAL.

right of access: technician
possible setting: 0-99h (0h)

t concentrate

function:

Duration of a CONCENTRATE
DISPLACEMENT/FLUSH process at the end of
a PRODUCTION (TANK FULL active).

right of access: technician
possible setting: 0-99min (1 min)

t min disposal

funtion:

Minimum duration of a DISPOSAL process at the
beginning of a PRODUCTION. This is the
minimum time after which the unit passes to
PRODUCTION if the value drops below LIM.

right of access: technician
possible setting: 0-999s (5s)

Attention: the set value must be less than t max
disposal. (Pay attention to units)

t max disposal

function:

Maximum duration of a DISPOSAL process. This
is the maximum time after which the value has to
be below LIM, otherwise a failure message will be
given.

right of access: technician
possible setting: 1-99min (60 min)

Attention: the set value must be greater than
t min disposal (Pay attention to units!)

t maintenance

function:

Operating time (hour meter) after which a signal
is given that maintenance has to be carried out
(flashing OPERATION).

right of access: technician
possible setting: 0-999999h (3500h)

Attention: zero setting means that no
maintenance message is given.