Karcher WATERCLEAN 600 CD User Manual

Page 74

Advertising
background image

74

APPENDIX

WTC 600 LP / MP

Service Handbook 08.2004

3

Operational Scope

3.1

Operating settings

The control system allows to preselect the following operating settings (realization see item 4).
The resulting control behaviours are described in the chapter Operating Conditions. The
standard values (setting after parameter reset) are marked by * in the appropriate field.

ps LIM high

function:

Preselect if unit is to be switched off if
LIM is exceeded or if a failure
message is sufficient

right of access:

user/technician

possible setting:

* switch off do
not switch off

ps acknowledgment

function:

Prelesect if acknowledgment of
failures is possible in the normal level
(=without password)
or only in the user/technician level
(=with password).

right of access:

technician

possible setting:

* without password
with password

ps concentrate mode

function:

Preselect if PRODUCTION has to be
followed by CONCENTRATE FLUSH
(with pump) or CONCENTRATE
DISPLACEMENT (without pump).

right of access:

technician

possible setting:

* flush
displacement

ps tank type

function:

Prelesect if tank is equipped with an
overflow or not. Should the tank have
an overflow, the produced water
continues to flow into the tank during
CONCENTRATE DISPLACEMENT/
FLUSH and DISCONTINUOUS
RINSE.

right of access:

technician

possible setting:

* with
without overflow