WTC 600 LP / MP

MAINTENANCE

Service Handbook 08.2004

4.5.2

Malfunction Indication at the Operating Panel

The control system detects operational malfunctions only while in operation operating mode;
these are indicated on the display. The occurrence of an error usually leads to the complete
system being switched off (production is interrupted).

Indication

Malfunction

Cause

Corrective Action

Chap./
Fig.

Motor/

Metering containe

Fill up

3.2

hard water

empty

Lack of pressure PI station gene-

No water

Establish the flow of

rates no pressure

available

untreated water again

Air in the pump

Bleed the pump; connect
pump directly in canal,
run for 30 sec.

Suction height too Ensure supply pressure
high, pump is not to the pump (mains
self-priming

supply, submerged
pump, ... )

Supply pressure of Flow rate through see 4.5.4
the reverse

preliminary filter

osmosis too low

too low

Differential

Filter soiled

Replace filter cartridge

4.1

pressure of the
preliminary filter
>>1 bar

Pressure switch

Replace pressure

2.2,

defective

switch (pay attention to

Pos. 4.9

setting)

Flow rate in sand

Filter clogged

Initiate backwashing

3.4.2

filter too low

Conductance

Permeate

Yield too high

Increase flow of

3.4.3.7

value

conductance value

concentrate

exceeded

too high

Very high salt

Check cause;

1)

content in

notify sales dept.

untreated water

Defective seal or Replace parts; switch off

ETL

membrane

system, if required

Conductance

Calibrate again;

ETL, SLP

value probe

replace if required

defective

Table 29

1)

See untreated water analysis, operational start-up record