Diagnostic error code

FRU/Action

000-250-XXX BIOS APM failure

1. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

2. System board

000-270-XXX BIOS ACPI failure

1. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

2. System board

001-000-XXX System test passed

No action

001-00X-XXX System error

System board

001-01X-XXX System error

System board

001-024-XXX System addressing test failure

System board

001-025-XXX System checksum value error

1. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

2. System board

001-026-XXX System FLASH data error

1. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

2. System board

001-027-XXX System configuration/setup error

1. Run Setup

2. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

3. System board

001-032-XXX System device controller failure

System board

001-034-XXX System device buffer allocation failure

1. Reboot the system

2. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

3. Run memory test

4. System board

001-035-XXX System device reset condition detected

System board

001-036-XXX System register error

System board

001-038-XXX System extension failure

1. Adapter card

2. System board

001-039-XXX System DMI data structure error

1. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

2. System board

001-040-XXX System IRQ failure

1. Power-off/on system and re-test

2. System board

001-041-XXX System DMA failure

1. Power-off/on system and re-test

2. System board

001-195-XXX System test aborted by user

Information only Re-start the test, if necessary

001-196-XXX System test halt, error threshold exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file