Lenovo 3980 User Manual
Page 55
Diagnostic error code
FRU/Action
001-279-XXX System IRQ12 failure
1. Device on IRQ12
2. System board
001-280-XXX System IRQ13 failure
1. Device on IRQ13
2. System board
001-281-XXX System IRQ14 (hard disk drive) failure
1. Hard disk drive cable
2. Hard disk drive
3. System board
001-282-XXX System IRQ15 failure
1. Device on IRQ15
2. System board
001-286-XXX 001-287-XXX 001-288-XXX System Timer
failure
System board
001-292-XXX System CMOS RAM error
1. Run Setup and re-test
2. System board
001-293-XXX System CMOS Battery
1. CMOS Battery
2. System board
001-298-XXX System RTC date/time update failure
1. Flash the system. See “Updating (flashing) BIOS
2. System board
001-299-XXX System RTC periodic interrupt failure
System board
001-300-XXX System RTC Alarm failure
System board
001-301-XXX System RTC Century byte error
1. Flash the system. See “Updating (flashing) BIOS
2. System board
005-000-XXX Video test passed
No action
005-00X-XXX Video error
1. Video card, if installed
2. System board
005-010-XXX 005-011-XXX 005-012-XXX 005-013-XXX
Video signal failure
1. Video card, if installed
2. System board
005-016-XXX Video simple pattern test failure
1. Video Ram
2. Video card, if installed
3. System board
005-024-XXX Video addressing test failure
1. Video card, if installed
2. System board
005-025-XXX Video checksum value error
1. Video card, if installed
2. System board
005-027-XXX Video configuration/setup error
1. Run Setup
2. Video drivers update
3. Video card, if installed
4. System board
Chapter 7
.
Symptom-to-FRU index
49