Diagnostic error code
FRU/Action
001-197-XXX System test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
001-198-XXX System test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Flash the system and retest. See “Updating (flashing)
3. Go to “Undetermined problems” on page 64
001-199-XXX System test failed, cause unknown
1. Go to “Undetermined problems” on page 64
2. Flash the system and re-test
3. Replace component under function test
001-250-XXX System ECC error
System board
001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX
System DMA error
System board
001-260-XXX 001-264-XXX System IRQ error
System board
001-268-XXX System IRQ1 failure
1. Device on IRQ1
2. System board
001-269-XXX System IRQ2 failure
1. Device on IRQ2
2. System board
001-270-XXX System IRQ3 failure
1. Device on IRQ3
2. System board
001-271-XXX System IRQ4 failure
1. Device on IRQ4
2. System board
001-272-XXX System IRQ5 failure
1. Device on IRQ5
2. System board
001-273-XXX System IRQ6 (diskette drive) failure
1. Diskette Cable
2. Diskette drive
3. System board
001-274-XXX System IRQ7 failure
1. Device on IRQ7
2. System board
001-275-XXX System IRQ8 failure
1. Device on IRQ8
2. System board
001-276-XXX System IRQ9 failure
1. Device on IRQ9
2. System board
001-277-XXX System IRQ10 failure
1. Device on IRQ10
2. System board
001-278-XXX System IRQ11 failure
1. Device on IRQ11
2. System board