Diagnostic error code

FRU/Action

006-197-XXX Diskette interface test warning

1. If a component is called out, make sure it is

connected and/or enabled

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

006-198-XXX Diskette interface test aborted

1. If a component is called out, make sure it is

connected and/or enabled

2. Flash the system and re-test. See “Updating

(flashing) BIOS from a disc” on page 99

3. Go to “Undetermined problems” on page 64

006-199-XXX Diskette interface test failed, cause
unknown

1. Go to “Undetermined problems” on page 64

2. Flash the system and re-test

3. Replace component under function test

006-25X-XXX Diskette interface Error

1. Diskette drive cable

2. Diskette drive

3. System board

015-000-XXX USB port interface Test Passed

No action

015-001-XXX USB port presence

1. Remove USB device(s) and re-test

2. System board

015-002-XXX USB port timeout

1. Remove USB device(s) and re-test

2. System board

015-015-XXX USB port external loopback failure

1. Remove USB device(s) and re-test

2. System board

015-027-XXX USB port configuration/setup error

1. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

2. System board

015-032-XXX USB port device controller failure

System board

015-034-XXX USB port buffer allocation failure

1. Reboot the system

2. Flash the system and re-test. See “Updating

(flashing) BIOS from a disc” on page 99

3. Run memory test

4. System board

015-035-XXX USB port reset condition detected

1. Remove USB device(s) and re-test

2. System board

015-036-XXX USB port register error

System board

015-040-XXX USB port IRQ failure

1. Run setup and check for conflicts

2. Flash the system. See “Updating (flashing) BIOS

from a disc” on page 99

3. System board

015-195-XXX USB port test aborted by user

Information onlyRe-start the test, if necessary

015-196-XXX USB port test halt, error threshold exceeded

1. Press F3 to review the log file