Installation, Input connections, Select suitable location – Lincoln Electric INVERTEC SVM129-B User Manual

Page 10

Advertising
background image

INSTALLATION

A-4

A-4

INVERTEC® STT® & STT® II

ELECTRIC SHOCK can kill.

Only qualified personnel should

perform this installation.

• Turn the input power OFF at the

disconnect switch or fuse box
before installing this
equipment.

• Turn the power switch on the Invertec

STT “OFF” before connecting or discon-
necting input power lines, output cables,
or control cables.

• Do not touch electrically hot

parts.

• Always connect the ground terminal to a

good electrical earth ground.

WARNING

MACHINE GROUNDING AND HIGH
FREQUENCY INTERFERENCE
PROTECTION

The machine may not be suitable for use in an envi-
ronment where high frequency is present. For exam-
ple do not place the machine in close proximity to “TIG”
or “PLASMA” operations. To minimize high frequency
interference:

Locate the STT II power source more than 15
feet (4.5 m) away from high frequency units
and more than 25 feet (7.6 m) separation
between ground connections or welding arcs
of high frequency units.

Provide proper electrical ground to the
machine per local and national electrical
codes.

INPUT CONNECTIONS

FAILURE TO FOLLOW THESE INSTRUCTIONS
CAN CAUSE IMMEDIATE FAILURE OF COMPO-
NENTS WITHIN THE WELDER.

Turn the input power off at the disconnect switch
before attempting to connect the input power lines.

Connect the green lead of the power cord to ground
per local and national electrical codes.

SUPPLY CONNECTIONS

Be sure the voltage, phase, and frequency of the input
supply is as specified on the rating plate. Input Power
supply line entry in provided on the case back of the
machine. See Figure A.1 for location of the rating
plate.

The Invertec STT II should be connected only by a
qualified electrician. Installation should be made in
accordance with local and national codes. Refer to the
Technical Specifications at the beginning of this sec-
tion for proper fuse sizes, ground wire, and input sup-
ply power cable sizes.

Some models come from the factory with an input
power cord. If your model does not include the input
power cord install the proper size input cable and
ground cable according to INPUT CABLE INSTALLA-
TION AND CONNECTION.

SELECT SUITABLE LOCATION

Locate the machine where there is free circulation of
clean air. Place the machine so that air can freely cir-
culate into the sides and out of the rear of the
machine. Dirt and dust that can be drawn into the
machine should be kept to a minimum. Failure to
observe these precautions can result in excessive
operating temperatures and nuisance shut down of the
Invertec STT II.

This machine carries an enclosure rating of IP21S. It
should not be placed in extremely damp or dirty loca-
tions. It should not be exposed to rain or snow.

STACKING

The Invertec STT II cannot be stacked.

TILTING

Place the machine on a secure, level surface otherwise
the unit may topple over.

Read and understand entire Installation
Section before starting installation.

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising