INVERTEC® STT® & STT® II

TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Machine loses output while weld-
ing. The thermal indicator light is
lit. Normal welding output returns
after about 10 minutes.

1. Check to make sure the fan is

running and operating correctly.

2. Welding

application

may

exceed recommended duty
cycle.

3. Dirt and dust may have clogged

the cooling channels. Blow out
the unit with clean, dry com-
pressed air.

4. Air intake and exhaust louvers

may be blocked due to inade-
quate clearance around the
machine.

1. The IGBT heat sink thermostat

or fan thermostat may be defec-
tive. Check or replace.