Troubleshooting & repair, T1 auxiliary transformer test (continued), Warning – Lincoln Electric INVERTEC SVM129-B User Manual

Page 53

Advertising
background image

TROUBLESHOOTING & REPAIR

F-15

F-15

INVERTEC® STT® & STT® II

5. Locate the primary lead molex plug (J21)

just behind the reconnect panel assembly on
the right side of the machine. Check for bro-
ken or loose wires. See Figure F.2.

6. Disconnect plugs J30 and J31 from the

wiring harness.

ELECTRIC SHOCK can
kill.

• With input power ON,

there are high voltages
inside the machine. Do
not

reach

into

the

machine or touch any
internal part.

7. Apply the correct input power to the machine

and test for the correct secondary voltages
at plugs J30 and J31. (Make sure the recon-
nect panel is configured properly for the
input voltage being applied.) See Table F.1.

T1 AUXILIARY TRANSFORMER TEST (continued)

RECONNECT

PANEL

PLUG J21

LOCATION BEHIND

RECONNECT PANEL

FIGURE F.2 – PRIMARY LEAD PLUG J21 LOCATION

WARNING