TROUBLESHOOTING & REPAIR

F-20

F-20

INVERTEC® STT® & STT® II

T4 AUXILIARY TRANSFORMER TEST (continued)

FIGURE F.3 – OUTPUT CHOKE/IGBT MODULE SPLICED CONNECTION

LOWER

TRAY

AREA

OUTPUT CHOKE/
DARLINGTON MODULE
SPLICED CONNECTION

TEST PROCEDURE

1. Turn off the INVERTEC® STT® & STT® II

and disconnect main AC input power to the
machine.

2. Using the 5/16" nut driver, remove the case

wraparound cover.

3. Perform the Input Filter Capacitor

Discharge

Procedure.

See

the

Maintenance section.

ELECTRIC SHOCK can
kill.

• Before continuing with

the test procedure, per-
form the capacitor dis-
charge procedure to
avoid electric shock.

4. Locate the lead connection splice from the

output choke to the IGBT module. Remove
the insulating sleeve. Cut any necessary
cable ties. Using the 7/16" wrench, discon-
nect the lead splice. Thread the lower lead
down into the lower tray assembly area.
See Figure F.3.