TROUBLESHOOTING & REPAIR

F-70

F-70

INVERTEC® STT® & STT® II

15. Place the machine on its side as shown in

Figure F.35. Slide the plastic retaining insu-
lators that go through the base of the
machine to one side. Pull the through-bolts
out of the machine, being careful to save all
the insulation and standoff material. Set
aside for reassembly.

16. Remove the switch board and capacitor

assembly from the machine.

FIGURE F.35 – REMOVING THROUGH-BOLTS

CAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)

PLASTIC RETAINING
INSULATORS