Troubleshooting & repair, Switch board replacement (continued), Warning – Lincoln Electric INVERTEC SVM129-B User Manual

Page 101

Advertising
background image

TROUBLESHOOTING & REPAIR

F-63

F-63

INVERTEC® STT® & STT® II

SWITCH BOARD REPLACEMENT (continued)

ELECTRIC SHOCK can
kill.

• With input power ON, there

are high voltages in the
machine. Do not reach
into the machine or touch
any internal part.

8. With the machine connected for 440/460 volt

operation and the proper input voltage
applied, turn on input power to the machine.

9. With the output free of a load, check open cir-

cuit voltages of the output. Voltage should be
85 VDC maximum.

10. Remove input power.

Then remove the

5-amp fuses from the input supply fuse hold-
ers.

11. Install 20-amp fuses and test under load.

NOTE: A resistive-type grid load bank is recom-

mended.

14. Perform Retest After Repair.

WARNING