Configuration, 2 u8/16-ip setup tool – Lindy 32530 User Manual

Page 13

Advertising
background image

Section 5 IP Access Configuration & Operation

24

5.1. Configuration

The U8/16-IP’s communication interfaces

are all based on TCP/IP. The switch comes

pre-configured with the following IP

configuration shown here:

If this initial configuration does not meet your requirements, the following section describes the

configuration that is necessary to access the U8/16-IP for the first time.

Initial Configuration via a DHCP Server

By default, the U8/16-IP will try to contact a DHCP server in the subnet to which it is physically

connected. If a DHCP server is found, it will provide a valid IP address, gateway address and

subnet mask. If a DHCP server is not available then you will need to assign a fixed IP

assignment to the MAC address of the IP Access Module. You can find the MAC address

details on the printed label on the underside of the IP Access module.

Before you connect the device to your local subnet, be sure to complete the corresponding

configuration using the setup tool supplied on the CD ROM. Follow the procedure described on

the next page

(Section 5.2)

Initial Configuration via a Serial Console

The U8/16-IP has a serial line interface (host side)

for connecting a serial terminal. This connector is

compliant with the RS-232 serial line standard. The

serial line has to be configured with the parameters

given in this table:

When configuring with a serial terminal, reset the U8/16-IP and immediately press the ESC key.

You will see some device information and a “=>” prompt. Type config and press the Enter key.

Wait a few seconds for the configuration information to appear.

As you proceed, the following questions will appear on the screen. To accept the default values

(shown in square brackets below) press the Enter key.

IP auto configuration (non/dhcp/bootp) [dhcp]:

IP [192.168.1.22]:

Net mask [255.255.255.0]:

Gateway (0.0.0.0 for none) [0.0.0.0]:

Parameter

Value

IP auto configuration

DHCP

IP-Address

-

Net-mask

255.255.255.0

Default-Gateway

none

Parameter

Value

Bits/second

115200

Data bits

8

Parity

No

Stop bits

1

Flow Control

None

Note:

If the DHCP connection fails on boot-up, the U8/16-IP will not be assigned an IP

address.

Section 5 IP Access Configuration & Operation

25

5.2 U8/16-IP Setup Tool

MAC Address Detection

Connect the U8/16-IP to your computer either via a local network, or via USB. If you use a USB

connection Windows will detect the U8/16-IP as a ‘Removable Disk’ and an appropriate drive

letter will be assigned.

Start the setup tool from the CD ROM.

A window opens as shown below:

On the upper left corner, the MAC address of the U8/16-IP is displayed. To re-detect the MAC

address, press the Refresh Devices button. The displayed MAC address should correspond to

the printed address shown on the label on the base of the IP module.

On the lower right corner of the window, there are two buttons: Query Device and Setup

Device. Press the Query Device button to display the preconfigured values of the network

configuration. The values are displayed in the text fields located above. If necessary, adjust the

network settings to your needs. To save the changes enter a user login and a password

(see

Authentication, below)

and then press the Setup Device button.