Lindy 32530 User Manual

Page 37

Advertising
background image

Section 5 IP Access Configuration & Operation

72

A new firmware update is a binary file which can be sent to you by email or which you can

download from our website www.lindy.com.

Updating the firmware is a four stage process:

1. The new firmware file is uploaded to the U8/16-IP. In order to do this you need to select the

file on your local system using the Browse button on the Upload Firmware panel. Once the

firmware file has been uploaded it is checked whether it is a valid firmware file and whether

there were any transmission errors. In case of any error the Upload Firmware function will be

aborted.

2. If everything went well you will see the Update Firmware panel. The panel shows you the

version number of the currently running firmware and the version number of the uploaded

firmware. Pressing the Update button will replace the old version with the new one.

3. After the firmware has been stored, the U8/16-IP will automatically reset itself. Half a minute

after the reset the U8/16-IP will run with the new firmware version and should be accessible.

However, you will be required to login once again.

4. Once you have logged in we recommend you delete the Temporary Internet Files from

your browser to ensure that the appearance of the web interface is correct. To do this in

Internet Explorer, select:

Tools > Internet Options > General > Delete Files

Tick the check box: Delete all offline content, and click OK

Tip: Should your keyboard fail to operate correctly, in the remote console, after a firmware

update please use the Reset Keyboard/Mouse option in the Maintenance section as

described on page 69

.

Note:

The firmware update process and consistency check means that making a mistake

when updating the firmware is very unlikely. However, we recommend only experienced

users or administrators should perform the firmware update. This process is not reversible

and may take some minutes. Make sure the U8/16-IP’s power supply will not be interrupted

during the update process!

Section 5 IP Access Configuration & Operation

73

Unit Reset

This section allows you to reset specific parts of the device. This involves the keyboard and

mouse, the video engine and the U8/16-IP itself.

Resetting the unit itself is mainly needed to activate a newly updated firmware. It will close all

current connections to the administration console and to the Remote Console.

The whole process will take about half a minute. Resetting sub devices (e.g. the video engine)

will take a few seconds only and does not result in connections closing. To reset individual

U8/16-IP functionality, click on the Reset button.

Note:

Only the super user is allowed to reset the U8/16-IP.