Select Venting System - Horizontal or Vertical

With the appliance secured in framing, de-

termine vent routing and identify the exterior

termination location. The following sections

describe vertical (roof) and horizontal (exterior

wall) vent applications. Refer to the section

relating to your installation.

A list of approved

venting components is shown on Pages 31

and 32.

Installation of Vent Restrictor

A vent restrictor may be needed with this ap-
pliance, install vent restrictor (provided) in the
appliance top flue outlet as shown in

Figure 18

(LMDV-3328, LMDV-3530 and LMDV-4035) or
rear flue outlet as shown in

Figure 19 (LMDV-

3328, LMDV-3530 and LMDV-4035). It is held
in place by friction, only.

Step 3. INSTALL THE VENT SYSTEM

General Information

These instructions should be used as a guide-

line and do not supersede local codes in any

way. Install vent according to local codes,

these instructions, the current National Fuel

Gas Code (ANSI-Z223.1) in the USA or the

current standards of CAN/CGA-B149.1 and

-B149.2 in Canada.

Use only approved venting components. See

Approved Vent Components on Page 2.

These fireplaces must be vented directly

to the outside.

The vent system may not service multiple

appliances, and must never be connected to a

flue serving a solid fuel burning appliance. The

vent pipe is tested to be run inside an enclosing

wall (such as a chase). There is no requirement

for inspection openings in the enclosing wall at

any of the joints in the vent pipe.

Preparing the Appliance Vent Collar on LMDV-

3530/4035 Series (Combined Top and Rear

Vent) Models.

Each of the unit's two vent collars are sealed

with a cover plate and a seal plate and gasket.

The cover, and seal plate and gasket must be

removed from the vent collar being used. Refer

to

Figure 16 for top vent usage and Figure 17

for rear, and the following steps to prepare the

appropriate collar for use.

From the vent collar being used, remove the four

screws securing the vent seal plate and gasket.

Remove and discard the seal plate and gasket.

When the top vent collar is being used, from

inside the firebox, loosen the two screws in the

keyhole slots of the cover plate and remove the

remaining two cover plate securing screws.

Remove and discard the cover plate. Reinstall

and securely tighten all four screws.

Figure 17

On LMDV-3530/4035 Series Models

(Combined Top And Rear Vent Units)

Rear Vent Seal & Cover Plate Removal

When Using The Rear Vent

When the rear vent collar is being used, from

inside the firebox, remove the two screws se-

curing the lintel to the rear wall of the firebox,

then remove the lintel. Remove the four cover

plate securing screws.

Remove and discard the cover plate. Rein-

stall and securely tighten all four cover plate

screws. Re-secure the lintel to the rear wall

of the firebox.

Cover Plate

Securing Screws

Top Vent

Vent Seal Plate

Firebox Top

(Inside of Appliance)

Figure 16

On LMDV-3530/4035 Series Models

(Combined Top And Rear Vent Units)

Top Vent Seal & Cover Plate Removal

When Using The Top Vent

(OUTSIDE of

Appliance)

Securing

Screws

Cabinet Top

CROSS SECTION

Vent Cover Plate

Gasket

Gasket

Lintel

Securing

Screws

Rear Vent

Lintel

(OUTSIDE of

Appliance)

(INSIDE of

Appliance)

CROSS SECTION

Securing

Screws

Vent Seal Plate

Cabinet

Back

Cover Plate

Securing Screws

WARNING

Failure to reinstall and securely

tighten cover plate screws could

result in leakage of flue products

into the living space. Vent cover

plate and vent seal plate must

remain securely installed on

unused vent collar. Failure to do

so could result in leakage of flue

products into living space.

Vent Restrictor Installation

(Top Vent)

A vent restrictor may be needed when vertical-

ly terminating the vent system above the roof

(when using the appliance top vent), install

vent restrictor in the top vent of the fireplace

outlet on LMDV-3530/4035 and LMDVT-3328

series models. If needed, install the restrictor

orientated as shown, either from inside or out-

side the unit,in the inner fireplace collar.

Appliance Top

Vent Outlet

Restrictor

Inner

Fireplace

Collar

VENT RESTRICTOR INSTALLATION

(REAR VENT)

A vent restrictor may be needed when horzontally

terminating the vent system from the rear of the

appliance (when using the appliance rear vent),

install vent restrictor in the rear vent of the fire-

place outlet on LMDV(R)-3328/3530/4035 series

models, in any installation that has a vertical vent

run in excess of three feet (0.914 meters).

If needed, install the restrictor orientated as

shown, either from inside or outside the unit,

in the inner fireplace collar

Inner Fireplace

Collar

Appliance Rear

Vent Outlet

Restrictor