Lennox Hearth Electronic LMDV-3530-CNM User Manual

Page 2

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

2

TABLE OF CONTENTS

Packaging .........................................Page 2

Introduction ......................................Page 2

General Information ..........................Page 2

New York City Approval .....................Page 3

Requirements for the

Commonwealth of Massachusetts .Page 4

Cold Climate Insulation .....................Page 4

Location ............................................Page 4

Manufactured Home Requirements ..Page 5

Vent Termination Clearances ............Page 5

Appliance and Vent Clearances .........Page 7

Detailed Installation Steps .................Page 8

Typical Installation Sequence ...........Page 8

Step 1. Framing .................................Page 8

Step 2. Routing Gas Line ..................Page 8

Fireplace Specifications .....................Page 9

Step 3. Install the Venting System ....Page 11

Vertical Termination Systems ............Page 12

Vent Section Length Chart ................Page 12

Vertical Vent Tables and Figures ........Page 14

Horizontal Termination System .........Page 16

Horizontal Vent Tables and Figures ...Page 19

Venting Using Flexible Vent Pipe .......Page 22

Step 4. Field Wiring .........................Page 23

Step 5. Optional Blower Kit Wiring ..Page 23

Step 6. Connecting Gas Line ...........Page 24

Step 7. Checking Unit Operation .....Page 25

Step 8. Installing Logs ...................Page 26

Step 9. Installing Glass Door ..........Page 29

Step 10. Burner Adjustments ............Page 29

Step 11. Hood Installation .................Page 30

Finishing Requirements ....................Page 30

Installation Accessories ....................Page 31

Gas Conversion Kits .................. Page 34

INTRODUCTION

These vented gas fireplace heaters are sealed

combustion, air circulating gas fireplaces de-

signed for residential applications.
Approved Vent Components - These fireplaces

are designed, tested and listed for operation

and installation with, the following vent com-

ponents only:

Secure Vent™ Direct Vent System Compo-

nents,

Secure Flex™ Flexible Vent Components

manufactured by Security Chimneys Inter-

national and

Z-FLEX™ Model GA Venting Systems listed

to UL1777 and ULCS635 manufactured by

Flexmaster Canada Limited.

These approved vent system components are

labeled for identification. DO NOT use any other

manufacturer’s vent components with these

appliances. Use only the correct size venting

(4-1/2" inner & 7-1/2" outer).
These appliances comply with National Safety

Standards and are tested and listed by OMNI-

Test Laboratories, Inc. (Report No. 116-F-31-5)

to ANSI Z21.88b (in Canada, CSA-2.33b), and

CAN/CGA-2.17-M91 in both USA and Canada,

as vented gas fireplace heaters.
Both millivolt and electronic versions of

these appliances are listed by OMNI-Test

Laboratories for installation in bedrooms

and Manufactured Homes.

Manufactured Homes -

See Manufactured Home Requirements on

Page 5 for additional information.

PACKAGING

The assembled vented gas fireplace heater is

packaged with:

1 - One log set located in firebox area.

2 - One envelope containing the literature pack-

age which consists of the homeowner's

manual, installation instructions, and war-

ranty; envelope is located in the control

compartment.

3 - One vent restrictor to be applied as shown on

Page 11 ; restrictor is taped to the envelope.

4 - One hood located behind the top panel.

5 - One bag of decorative volcanic stone located

in the control compartment.

6 - One bag of glowing embers located in the

control compartment.

7 - One bag of vermiculite located in the control

compartment.

WARNING

Improper installation, adjust-

ment, alteration, service or

maintenance can cause injury

or property damage. Refer to

this manual. For assistance or

additional information consult

a qualified installer, service

agency or the gas supplier.

This appliance is only for use with the type

of gas indicated on the rating plate. This ap-

pliance is not convertible for use with other

gases, unless a certified kit is used.

Cet appareil doit être utilisé uniquement

avec les types de gaz indiqués sur la plaque

signalétique. Ne pas l'utiliser avec d'autres

gaz sauf si un kit de conversion certifié est

installé.

Misc. Codes / Standards -

Installation must conform to local codes. In the

absence of local codes, installation must comply

with the current National Fuel Gas Code, ANSI

Z223.1. (In Canada, the current CAN-1 B149

installation code).

The appliance, when installed, must be elec-

trically grounded & wired in accordance with

local codes or, in the absence of local codes,

with the National Electrical Code, ANSI / NFPA

70-latest edition, or the Canadian Electrical

Code, CSA C22.1 - latest edition.

GENERAL INFORMATION

Note: Installation and repair should be per-

formed by a qualified service person. The

appliance should be inspected annually by a

qualified professional service technician. More

frequent inspections and cleanings may be

required due to excessive lint from carpeting,

bedding material, etc.

S'assurer que le brùleur et le compartiment des

commandes sont propres. Voir les instructions

d'installation et d'utilisation qui accompagnent

l'appareil.

Provide adequate clearances around air open-

ings and adequate accessibility clearance for

service and proper operation. Never obstruct

the front openings of the appliance.

These appliances are designed to operate on

natural or propane gas only. The use of other

fuels or combination of fuels will degrade

the performance of this system and may be

dangerous.

These fireplaces are designed as supplemen-

tal heaters. Therefore, it is advisable to have

an alternate heat source when installed in a

dwelling.

Millivolt Models - The millivolt appliances are

manually controlled and feature a spark igniter

(piezo) that allows the appliance's pilot gas to

be lit without the use of matches or batteries.

This system provides continued service in the

event of a power outage.

Millivolt models come standard with a manu-

ally-modulated gas valve; flame appearance and

heat output can be controlled at the gas valve.

The BTU Input for these appliances is shown

in Tables 1 & 2.

The Millivolt appliances have a millivolt gas

control valve with piezo ignition system which

provides safe, efficient operation. If any optional

accessories that will require electrical power

are to be installed, the electrical power must be

provided at the time of appliance installation.
The

Electronic appliances have an electronic

intermittent pilot ignition system which provides

safe, efficient operation. External electrical pow-

er is required to operate these appliances.

This manual is part of a set of two supporting

this product. Refer to manual 875,028M for

Care & Operation information.

Please read and understand these

instructions before beginning your

installation.

Advertising