NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Electronic Models -

Electronic models have a fixed rate gas valve.

Input of electronic models is shown in

Table 3.

Electronic Models with Fixed Rate Gas Valve

Natural and Propane Gas

Model Series

Input Rate

(BTU / HR)

LMDVT-3328

LMDVR-3328

17,500

LMDV-3530

20,000

LMDV-4035

27,000

Table 3

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

LMDVT-3328

LMDVR-3328

#45 (.082")

*

39L66 •

(.048")

*

99K780

LMDV-3530

#44 (.086")

*

60J8001 •

#55 (.052")

*

19L5201

LMDV-4035

#37 (.104")

*

24M1001 •

1/16" (.062")

*

21L0101 •

Table 7

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 4

Gas Pressure - All Models

Tables 4, 5 and 6 show the appliances' gas

pressure requirements:

Manifold Gas Supply Pressure

(millivolt models)

Fuel #

Low

High

Natural

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 5

Manifold Gas Supply Pressure

(electronic models)

Fuel #

Maximum Manifold Pressure

Natural Gas

(Hi) 3.5" WC (.87 kPa)

Propane

(Hi) 10.0" WC (2.49 kPa)

Table 6

Test gauge connections are provided on the

front of the millivolt gas control valve, identi-

fied IN for the inlet and OUT for the manifold

side. A 1/8" NPT Test gauge connection

is provided at the inlet and outlet side of

the electronic gas control valve.

Orifice Sizes - Sea Level to High Altitude

(All Models)

These appliances are tested and approved for

installation at elevations of 0-4500 feet (0-1372

meters) above sea level using the standard burner

orifice sizes (marked with an "*" in Table 7). For

elevations above 4500 feet, contact your gas

supplier or qualified service technician .

Gas Valve Diagrams

See Figures 1 & 2 for Millivolt models and

Figure 3 For Electronic Models.

Figure 3

Honeywell Electronic Gas Valve

FF

O

NI

P

S

I

N

O

L

O

RT

N

O

C

GI

N

TIER

Manifold Pressure

Port

ON / OFF Switch

Inlet

Pressure

Port

Electronic

Gas

Control

Valve

O N

OFF

PIL

OT

LO

H

I

Figure 2

GAS CONTROL

KNOB

CONVERTIBLE

HI/LO REGULATOR

(adjusts flame height

and heat output)

INLET

PRESSURE

TAP

PILOT

ADJUSTMENT

SCREW

WIRING

TERM-

INALS

OUTLET

PRESSURE

TAP

TP/TH

PIEZO

IGNITER

TH

TP

Honeywell Millivolt Gas Valve

These appliances must be isolated from the

gas supply piping system (by closing their

individual manual shut-off valve) during any

pressure testing of the gas supply piping

system at test pressures equal to or less than

1/2 psig (3.5 kPa).
These appliances and their individual shut-off

valves must be disconnected from the gas

supply piping system during any pressure

testing of that system at pressures greater

than 1/2 psig (3.5 kPa).

Install the appliance according to the regulations

of the local authorities having jurisdiction and,

in the USA, the National Fuel Gas Code NFPA 54

/ ANSI Z223.1 - latest edition or, in Canada, the

CAN1-B149.1 and .2 codes - latest edition.

Input (BTU) Manually-Modulated Gas

Valves (millivolt models)

NATURAL GAS

Models

Input Rate (BTU / HR)

LMDVT-3328CNM

LMDVR-3328CNM

17,500 high

11,700 low

LMDV-3530CNM

20,000 high

12,800 low

LMDV-4035CNM

27,000 high

18,500 low

Table 1

Input (BTU) Manually-Modulated Gas

Valves (millivolt models)

PROPANE GAS

Models

Input Rate (BTU / HR)

LMDVT-3328CPM

LMDVR-3328CPM

17,500 high

14,000 low

LMDV-3530CPM

20,000 high

15,200 low

LMDV-4035CPM

27,000 high

21,500 low

Table 2

HI

LO W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

it

OFF

IN

OUT

Manifold Pressure Tap

Inlet Pressure Tap

SIT Millivolt Gas Valve

Pilot Adjustment

Screw

HI/LO Variable

Flame Height

Adjustment

Main Gas

Control Knob

OFF/PILOT/ON

Figure 1

* Standard size installed at factory

• Part /Cat. Number