Caution – Lennox Hearth Electronic LMDV-3530-CNM User Manual

Page 23

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

23

Figure 46

See Figure 14 on Page 9

for Optional Electrical

Inlet Knockout Location

Step 4. FIELD WIRING

3. Connect the power supply wires (including

the ground supply wire) as shown in

Figure

47. (If the field-provided J-box/outlet box is

being used, all of the outlet box wiring must
be field-provided).

4. Locate and install a low voltage (24V) wall-

mounted switch or thermostat (both field-
provided)in the desired location.

5. Connect the low voltage wire, located inside

the control compartment, to the wall-mounted
switch or thermostat.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected to
the gas valve circuit and the other end of each
conductor placed loose inside the control
compartment.

6. Insert the control circuit plug into the un-

switched receptacle of the outlet box.

7. After wiring is complete, mount the outlet box

to the J-Box.

Note: The gas valve-mounted ON/OFF switch is
shown in Figure 47. It is integral with the gas
valve and should be set to the ON position.

Step 5.

WIRING - OPTIONAL FORCED AIR

BLOWER KIT

FBK-100, FBK-200 and FBK250 Kits
(See Figure 47) -

An electrical outlet box (receptacle) is factory
-provided for the installation of the FBK-100,
FBK-200 and FBK-250 forced air blower kits.
(An optional field-provided outletbox/J-Box
may also be used. Electrical power must be
connected to either of these receptacles in order
to operate these blowers. Install the blower
kits according to the installation instructions
provided with the kits.

3. Wire the control within the millivolt control

circuit using the 15 feet of 2 conductor wire

supplied with the unit .

Caution: do not

connect the optional wall switch to a 120V

power supply.

4. Alternatively, the appliance may be operated

without the use of the controls indicated in

step 1, solely by manipulating the gas valve

control knob. In order to use this method,

twist the free ends of the two conductor wire

(which would otherwise go to the standard

ON/OFF switch or Optional Switch) together

as shown in

Figure 45. Note: Wire is located

inside the control compartment

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected to

the gas valve circuit and the other end of each

conductor placed loose inside the control

compartment.

B. Electronic Wiring (See Figure 47)

Note: The electronic appliance must be con-

nected to the main power supply.

The junction box is located on the right side of
the appliance. It contains a factory installed and
wired outlet box (duplex receptacle). Also, an
optional field-provided junction box with recep-
tacle may be installed at the front of the control
compartment on either side of the cabinet.

See

Figure 46. It will be held in place by a conduit
fitting and locknut (field-provided).

1. Route a 3-wire 120Vac 60Hz 1ph power supply

to the appliance junction box.

2. If the factory-provided outlet/junction box at

the right rear of the fireplace is being used,

remove the outlet box from the junction box

by removing two screws.

*Field-Provided

Junction Box

and Duplex

Receptacle

*Narrow (2 1/8" Wide)

J-Box Required

Optional J-Box/Outlet

Box (Left Side Shown)

CAUTION

Ensure that wires are positioned

away from hot surfaces and sharp

edges.

CAUTION

Do not connect the optional wall

switch for burner operation to a

120 Volt AC power supply.

CAUTION

Label all wires prior to discon-

nection when servicing controls.

Wiring errors can cause improper

and dangerous appliance opera-

tion.

Refer to Section A for millivolt appliances and

Section B for electronic appliances. The gas

valve is set in place and pre-wired at the factory

on both models.

A. SIT and Honeywell Millivolt Wiring

(See Figure 45)

1. Select any of the following optional controls:

appliance-mounted (rocker switch) or wall-

mounted switch, thermostat, or one of the

optional remote control kits. If appliance-

mounted ON/OFF control is selected mount

it in the gas valve mounting bracket.

2. If wall-mounted ON/OFF control or ther-

mostat is selected mount it in a convenient

location on a wall near the fireplace.

Figure 45 -

Millivolt Wiring Diagram

Field Wired

Factory

Wired

TH

TP

TH

TP

* Optional

Control Switch

Thermopile

Schematic
Representation
Only

• If any of the original wire as supplied must

be replaced, it must be replaced with Type AWM

105 C - 18 gage wire.

* Optional Kits Installed - ON/OFF wall switch, unit mounted burner ON/OFF switch, wall thermostat or

remote control.receiver.

HT

PT

HT

PT

*

* Twist wires together to operate unit

solely by manipulating the gas valve

control knob; or connect wires to

optional control switch (wall switch,

remote control or wall thermostat to

operate unit.