Lfc 3000 user’s manual series “a – Lincoln LFC 3000 User Manual

Page 10

Advertising
background image

Page Number - 10

LFC 3000 User’s Manual

Series “A”

Form 403082

System Menu

Set Ticket B Adr.

To fulfill all the needs of the garage supervisor, LFC 3000

offers also the flexibility to print a copy of the transaction

tickets. All the printers must be connected through the serial

port and be Epson emulated. This printer can be the main

printer. This instruction must be done on EACH keypad. The

factory default setting is ticket B address on keypad 0.

Ticket B Address

I/O Control Unit

ENTER: The ticket B printer is connected on the I/O unit

(ID=0)

Use Up / down keys to select.

Ticket B Address

None

ENTER: There is no ticket B printer on the system.

Use Up / Down keys to select

Ticket B Address

Keypad x

ENTER: The ticket B printer is connected on the keypad

Number x.

Use Up / Down keys to select the address

ENTER

System Menu

Set System PIN

The system PIN code can be modified. Only numerical PIN

is accepted by the system. If the system PIN Number has

been forgotten, it will be necessary to reset the system and

re-configure. See Instruction Manual, under Troubleshoot-

ing, “Lost Supervisor PIN.”

ENTER

System Cfg PIN

****

LFC 3000 operates all the hose reels simultaneously or one

hose reel at a time. When the system is configured in

simultaneous mode, you will be able to dispense on all the

different hoses at the same time.

The factory default setting is simultaneous.

System Menu

Set Simultaneous Mode

ENTER

Set Simultaneous Mode

Non-Simultaneous

Use Up / down keys to select.

Set Simultaneous Mode

Simultaneous

In a multi I/O system without PC, this parameter must

programmed and must be the same on each I/O

ENTER

System Menu

Pulses per Liter

LFC 3000 is designed to register pulses from 1 to 255 per

liter. Refer to the type of pulse transmitter. To change to

“pulses per quart” see user menu, “Set Language”, change

to American English.

Pulse per Liter

100

In a multi I/O system without PC, this parameter must

programmed and be the same and on each I/O.

ENTER

System Menu

Max. Dispense

ENTER

Select Hose

0

Max. Dispense

_ 100

ENTER the maximum quantity that will be allowed to be

dispensing on the selected hose.

Then press ENTER and do the same for the other hoses.

System Menu

Decimal Place

Decimal Place

1

You can choose the place of the decimal. You only have 1 or

2 (use the Up / down arrow key).

( You also have to change physically the jumper located in

the display). ENTER