Form 403082

LFC 3000 User’s Manual

Series “A”

Dispense Mode

Pre-Select - Free Dispense

Customer Menu

Odometer & Reg.

With the LFC 3000 you can store the odometer reading and

the license plate number of the vehicles maintained in the

garage. This information will appear on the transaction

ticket;

ENTER

Odometer & Reg.

Yes

Use Up / Down keys to select

The keypad will always ask the operator to store the

odometer and registration plate of the vehicle

corresponding to the job number.

Odometer & Reg.

No

The function will not be activated.

Customer Menu

Initial Timeout

The initial time-out is the time between the validation of the

transaction data’s on the keypad and the opening of the

solenoid valve corresponding to the selected hose. Enter

the maximum number of seconds necessary before starting

the operation.

In a multi I/O system without PC, this parameter must

programmed and be the same and on each I/O.

ENTER

Initial Timeout

06

Customer Menu

Inactive Timeout

The inactive timeout is the period between the last pulse

received by the system and the closing of the solenoid. The

LFC 3000 will close the transaction if the time between 2

pulses reaches the inactive-time configured in the system.

It is visualized that the operator has started to fill the vehicle

with oil and that he has stopped the dispense before the

pre-set quantity has been reached or because he is work-

ing in the free dispense mode. When choosing this dura-

tion, bear in mind that this should be long enough for your

worker to verify the oil level on the dip stick. Enter the

maximum number of seconds needed.

Customer Menu

Warn Level

A minimum stock level must be set for each tank. All fluids

dispenses will automatically be deducted from the respective

tank stock. When the stock level in the tank reaches the warn-

ing level, a warning reordering message will automatically be

printed on the report printer.

ENTER

Use Up / Down arrow key to select the tank

Warn Level

Tank 1 = _ _ _ _

ENTER

Warn Level

_ _ _ _ 0

Enter the minimum stock level

ENTER

Warn Level

400

Customer Menu

Stop Level

In addition to the “minimum level”, the LCF 3000 offers the

ability to set up “stop levels” for each tank, preventing

dispenses of the selected product when the level in the tank

is under the stop level limit. This will prevent air to enter in

the oil line and prevent any risk of impurities entering the

line as well.

ENTER

Stop Level

Tank 1 = _ _ _ _ 0

Choose the tank you want to configure.

ENTER

New Stop Level

_ _ _ _ 0

Customer Menu

Dispense Mode

The LFC 3000 offers the possibility for the operator to

dispense oil in Pre-Select or in free dispense mode. In Pre-

select mode, the system will not authorizes any dispense

without a pre-selected quantity of fluid. In free dispense, the

system will authorize dispenses without pre-selection of any

quantity.

The system will close the transaction when the inactive

time-out has been reached.

ENTER

Use Up / Down key to select the mode.