Form 403082

LFC 3000 User’s Manual

Series “A”

Report Address

I/O Control

ENTER: The report printer is connected to an I/O unit

(ID=0). Use Up / Down key to select

Report Address

Keypad x

ENTER: The report printer is connected on the keypad

number X.

Use Up / Down key to select until you have the correct

address.

ENTER

Report Address

None

ENTER: There is no report printer on the system.

Use Up/Down keys to select.

ENTER

System Menu

Set Ticket A Adr.

To fulfill all the needs of the garage supervisors, LFC 3000

offers the flexibility to print the transaction tickets on different

printers. All the printers must be connected through the

serial port and be Epson emulated. This instruction must

be done on EACH keypad.

The Factory default setting is Ticket A address on Keypad 0.

ENTER

Ticket A Address

I/O Control Unit

ENTER: The ticket A printer is connected on the I/O unit

(ID=0)

Use Up / Down keys to select.

Ticket A Address

Keypad X

ENTER: The ticket A printer is connected on the keypad

number X.

Use Up/Down key to select the address.

ENTER

Ticket A Address

None

ENTER: There is no ticket A printer on the system.

Use Up/Down keys to select.

ENTER

Every display is delivered with dip switches on the PC

board. See Instruction Manual, “Wiring the display.”

ENTER

Select Hose

01

ENTER

Select Display

00

ENTER

Hose Number 1 will be visualized on display Number 00.

System Menu

Set Encoder Type

LFC 3000 allows the use of single channel and dual

channels pulse transmitters.

By default, all the systems are programmed to be use with

single channel pulse transmitters.

ENTER

Set Encoder type

Quadrature

Quadrature corresponds to dual channel pulse transmitter.

Use Up / Down keys to select.

Set Encoder type

Single Channel

Single channel pulse transmitter.

In a multi I/O system without PC, this parameter must be

programmed and be the same on each I/O.

ENTER

System Menu

System Type

System Type

Non-Master

Use Up / Down keys to select.

Non-Master is used without PC.

Master is used with PC.

ENTER

System Menu

Set Report Adr.

A “Main” printer is necessary to print the entire statistic, stock

level reports and diagnostic.

This printer must be 80 columns; Epson emulated with a

serial port.

The factory default setting is report address on Keypad 0.

ENTER