INSTALLATION


Standard Vertical Installation Configurations - Model:
Advantage II-T C FS - These freestanding models may be con-
nected to an existing unused flue or by installing type “PL” vent pipe (listed to UL 641 & ULC S609). If a liner is run all the way
to the top of the existing chimney, the existing flue should be sealed with a steel plate. Start a vertical run with a Tee at the
back of the stove. Other options are illustrated below. Note: See page 13 for Vent Termination Requirements.

PAGE 18

Exterior Vertical Vent

Vertical Vent Into A Masonry Flue

Preferred Installation – Vertical Vent Through the Roof

This venting configuration allows for the best stove
performance. The vertical pipe promotes natural draft
and with the chimney inside the dwelling, the flue
gases stay warm, thus rising at a consistent rate.

Interior Vertical Vent into an

Existing Class A Chimney

Wall Straps Re-
quired Every 4 ft.
Minimum

Optional Complete
Liner and Listed
Termination Cap

Optional Clean-
Out Access
Door

Listed Rain Cap

See Page 14 Vent
Termination Re-
quirements

Clean-Out
Tee

3”

Min

.

Existing
Chimney
Pipe

Pipe Increaser

3”

Min.

Extend Pipe to
the Top if Exist-
ing Chimney is
Corroded or
Damaged

www.PelletKing.com