Specifications - advantage ii-t c ins – Lennox Hearth II-T C FS User Manual

Page 32

Advertising
background image

SPECIFICATIONS - Advantage II-T C INS

PAGE 32

Flue Size

3” Standard

Width, Overall front (w/o surround)

25”

Width, Overall back (w/o surround)

24 1/4”

Depth, Overall (w/o surround)

24 3/4”

Height, rear (w/o surround)

19 3/4”

Height, front (w/o surround)

22 3/4”

Floor to Rear

Flue Center

8 1/2”

Fireplace Face to Rear

Flue Outlet Center (3” tee)

17 3/8”

Dimensions into Fireplace

Minimum Height

20 1/8”

Minimum Width @ Front

(extends back 1 ½”)

32”

Minimum Width @ Back

24 5/8”

Minimum Depth

17 3/4”

Facing Back of Unit,

Right Outside Edge of Unit

to Center of Rear Flue Outlet

5”

Floor to Rear

Outside Air Inlet

1 5/8"

Facing Back of Unit,

Right Outside Edge of Unit

to Center of Air Inlet

13”

Floor Protection

Requirements

Front:

• 6”

Standard Features

Fastfire

 Self Igniter

Wall

Thermostat

(wire

included)

Hopper Capacity

60 lbs.

Burn time

♦ 13-46 hours

Fuse, Control Board

5 Amp, 250 VAC *

Fuse, Igniter

6 Amp, 125 volt *

Heat Input (Max.)

♦ 11,000-38,000 BTU / hr

Emissions

♦ 2.3 gr / hr (varies w/size

and type of fuel) EPA

Certified.

Ship Weight

200 lbs.

Auger Motor

1 RPM; .55 Amps

Room Air Blower

150 CFM; 1.5 Amps

Exhaust Blower

95 CFM: .95 Amps, 3000

rpm

Options Log

Set

Gold

Trivet

Surround Trim Kit, Gold

FRONT VIEW

SIDE VIEW

Note: Dimensions shown are approximations only (+/-
1/4”)

An approved fireplace hearth or hearth extension is

required 6" to the front of the door. The hearth exten-

sion / floor protector used must be thermal rated (k =

.84, r = 1.19). See Floor Protection, page 5.

Fuel delivery and burn times will vary depending

on size and type of fuel used. Estimated heat in-
put based on fuel value of 8400 BTU per lb.

* Fuses are rated as fast blow.

24 ¾"

Sm. 40 ¾", Med. 44", Lg. 48"

Sm. 28 ½"
Med. 32"
Lg. 36"

www.PelletKing.com

Advertising
This manual is related to the following products: