TROUBLESHOOTING & REPAIR

F-61

F-61

LINCOLN

®

ELECTRIC

IDEALARC DC-400

RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

INPUT IDLE AMPS AND WATTS

Input volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

200/3/60

10.9

1.2

208/3/60

10.5

1.2

220/3/60

9.9

1.2

230/3/60

9.5

1.2

380/3/60

5.8

1.2

400/3/60

5.5

1.2

415/3/60

5.3

1.2

440/3/60

5.0

1.2

460/3/60

4.8

1.2

500/3/60

4.4

1.2

575/3/60

3.8

1.2

200/3/50

19.8

1.3

220/3/50

18.0

1.3

230/3/50

17.2

1.3

380/3/50

10.4

1.3

400/3/50

9.9

1.3

415/3/50

9.5

1.3

440/3/50

9.0

1.3

500/3/50

7.9

1.3

OPEN CIRCUIT VOLTAGES

Mode

Input Hertz

Open Circuit Volts

Constant Current

60

54/58

Constant Current

50

51/55

Constant Voltage

60

42.5/46.5

(FCAW/GMAW)

50

42.5/46.5

Constant Voltage

60

43.5/47.5

(SUB ARC)

50

43.5/47.5

Auxiliary Output (#31-#32)

60

114/124

Auxiliary Output (#31-#32)

50

109/119

Auxiliary Output (#41-#42)

60

43.8/47.5

Auxiliary Output (#41-#42)

50

42.0/45.6