ACCESSORIES

C-9

C-9

LINCOLN

®

ELECTRIC

IDEALARC DC-400

FIGURE C.7

IDEALARC DC-400/LN-7 WITH K584 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM

SEMIAUTOMATIC WIRE FEEDERS

CONNECTING THE LN-7 TO THE IDEALARC
DC-400 (14-PIN AMPHENOL)

1.

Disconnect main AC input power to the Idealarc
DC-400.

2.

Set the POWER toggle switch to the OFF (0) posi-
tion.

3.

Connect the electrode cable from the K584-XX
Input Cable Assembly to the “+” terminal of the
welder and to the LN-7 wire feeder. Connect the
work cable to the “-” terminal of the welder.
Reverse this hookup for negative polarity.

NOTE: Welding cable must be sized for the current

and duty cycle of the application.

4.

Connect K584-XX Input Cable between the DC-
400 and the LN-7. See Figure C.7.

5.

Set the welder VOLTMETER toggle switch to the
desired polarity, either DC (-) or DC (+).

6.

Set the MODE switch to a CV (constant voltage)
position at the welder.

7.

Adjust wire feed speed at the LN-7 and set the
welding voltage with the OUTPUT CONTROL.

NOTE: If optional remote control is used, place the

OUTPUT CONTROL and the OUTPUT TERMI-
NALS switch in the “Remote” position.