TROUBLESHOOTING & REPAIR

F-6

F-6

LINCOLN

®

ELECTRIC

IDEALARC DC-400

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

The input contactor operates – the
fan runs – the pilot light is lit – but
the machine has no welding out-
put.

1. If the amber thermal protection

light is lit, the primary or sec-
ondary thermostat is open.
Allow machine to cool.

2. Make certain the output trigger

circuit (#2 and #4) is being acti-
vated either by an external “clo-
sure” or by the output terminals
switch (S3).

3. Check the 10A circuit breaker in

the 42VAC line.

4. If remote control is not being

used, make certain the Output
Control switch (S2) is in the
OUTPUT CONTROL “LOCAL”
position.

5. Check for loose or faulty weld

cable connections.

1. Perform the Main Transformer

Test.

2. Perform

the

SCR/Diode

Rectifier Bridge Test.

3.

The control board may be
faulty. Replace.