5.

Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.

a.

Make a bolted connection using AWG #14 or
larger insulated wire. Tape the bolted connec-
tion with insulating tape.

b.

An S-16586- X remote voltage sensing work
lead is available for this purpose.

c.

Keep the #21 lead electrically separate from
the work cable circuit and connection.

d.

Tape the #21 lead to work cable for ease of
use.

6.

Connect NA-5 wire feeder control jumpers on
Voltage Control Board. See NA-5 Operator’s
Manual.

NOTE: The connection diagram shown in Figure C.5

shows the electrode connected for positive
polarity. To change polarity:

a.

Set the Idealarc DC-400 POWER toggle
switch to the OFF (0) position.

b.

Move the electrode cable to the negative (-)
output terminal.

c.

Move the work cable to the positive (+) output
terminal.

d.

Set the VOLTMETER toggle switch to negative
(-).

NOTE: For proper NA-5 operation, the electrode

cables must be secured under the clamp bar
on the left side of the NA-5 Control Box.

7.

Set the DC-400 OUTPUT CONTROL switch to the
“Remote” position and the OUTPUT TERMINALS
switch to the “Remote” position.

CONNECTING THE NA-3 OR NA-5 TO THE
IDEALARC DC-400 (14-PIN AMPHENOL)

1. Disconnect main AC input power to the Idealarc

DC-400.

2. Set the Idealarc DC-400 POWER switch to the OFF

(0) position.

3. Connect the electrode cable from the K597-XX

Input Cable Assembly to the “+” terminal of the
welder and to the wire feeder. Connect the work
cable to the “-” terminal of the welder. Reverse this
hookup for negative polarity. See Figure C.6.

NOTE: Welding cable must be sized for the cur-

rent and duty cycle of the application.

4. Set the welder VOLTMETER switch to the desired

polarity, either DC (-) or DC (+).

5. Set the MODE switch to a CV (constant voltage)

position.

6.

Set the DC-400 OUTPUT CONTROL switch to the
“Remote” position and the OUTPUT TERMINALS
switch to the “Remote” position.

ACCESSORIES

C-8

C-8

LINCOLN

®

ELECTRIC

IDEALARC DC-400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE C.6

IDEALARC DC-400/NA-3/NA-5 14-PIN AMPHENOL CONNECTION

TO NA-3 or NA-5 INPUT
CABLE PLUG

K597-XX INPUT CABLE ASSEMBLY

Advertising