CONNECTING THE LN-8 OR LN-9 TO THE
IDEALARC DC-400 (TERMINAL STRIP)

1.

Disconnect main AC input power to the Idealarc
DC-400.

2.

Set the Idealarc DC-400 POWER toggle switch to
the OFF (0) position.

3.

Connect the wire feeder control cable leads to the
Idealarc DC-400 terminal strip as shown in Figure
C.9.

4.

Connect the wire feeder control cable ground lead
to the frame terminal marked .

5.

Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.

a. Make a bolted connection using AWG #14 or

larger insulated wire. Tape the bolted connec-
tion with insulating tape.

b. An S-16586- X remote voltage sensing work

lead is available for this purpose.

c. Keep the #21 lead electrically separate from

the work cable circuit and connection.

d. Tape the #21 lead to work cable for ease of

use.

NOTE: Using the extended #21 lead eliminates

the need to use the LN-9’s remote work
lead accessory, which has a direct work
lead jack.

6.

Connect LN-9 wire feeder control jumpers on
Voltage Control board. See LN-9 Operator’s
Manual.

NOTE: The connection diagram shown in Figure C.9

shows the electrode connected for positive
polarity. To change polarity:

a. Set the Idealarc DC-400 POWER toggle

switch to the OFF (0) position.

b. Move the electrode cable to the negative (-)

output terminal.

c. Move the work cable to the positive (+) output

terminal.

d. Set the VOLTMETER toggle switch to negative

(-).

7.

Set the OUTPUT CONTROL switch to the
“Remote” position and the OUTPUT TERMINALS
switch to the “Remote” position.

ACCESSORIES

C-11

C-11

LINCOLN

®

ELECTRIC

IDEALARC DC-400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE C.9 - LN-8 OR LN-9 WIRE FEEDER CONNECTION TO THE IDEALARC DC-400