Accessories – Lincoln Electric IDEALARC SVM 122-A User Manual

Page 30

Advertising
background image

FIGURE C.4 – NA-3 WIRE FEEDER

CONNECTION TO THE IDEALARC DC-400

5.

Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.

a.

Make a bolted connection using AWG #14 or
larger insulated wire. Tape the bolted connec-
tion with insulating tape.

b.

An S-16586- X remote voltage sensing work
lead is available for this purpose.

c.

Keep the #21 lead electrically separate from
the work cable circuit and connection.

d.

Tape the #21 lead to work cable for ease of
use.

NOTE: The connection diagram shown in Figure C.4

shows the electrode connected for positive
polarity. To change polarity:

a.

Set the Idealarc DC-400 POWER toggle
switch to the OFF (0) position.

b.

Move the electrode cable to the negative (-)
output terminal.

c.

Move the work cable to the positive (+) output
terminal.

d.

Set the VOLTMETER toggle switch to nega-
tive (-).

6.

Set the DC-400 OUTPUT CONTROL switch to the
“Remote” position and the OUTPUT TERMINALS
switch in the “Remote” position.

CONNECTING THE NA-5 TO THE
IDEALARC DC-400 (TERMINAL STRIP)

1.

Disconnect main AC input power to the Idealarc
DC-400.

2.

Set the Idealarc DC-400 POWER toggle switch to
the OFF (0) position.

3.

Connect the wire feeder control cable leads to the
Idealarc DC-400 terminal strip as shown in Figure
C.5.

FIGURE C.5 – NA-5 WIRE FEEDER

CONNECTION TO THE IDEALARC DC-400

NOTE: If using a K215 control cable, connect

control cable leads #75, #76, and #77 to
the matching #75, #76, and #77 terminals
on the terminal strip of the Idealarc DC-
400.

4.

Connect the wire feeder control cable ground lead
to the frame terminal marked .

NOTE: The Idealarc DC-400 must be properly

grounded.

ACCESSORIES

C-7