Link Interfaces Reference

3.2

— IOLINK-PRO & 520 Reference Manual

The IOLINK-PRO and 520 routers are currently produced with LXT CSU/DSU interface modules which

have their link speed configured in software (please see the PPP menus manual for configuration options);

however, the earlier model ATL CSU/DSU module is still compatible with the IOLINK router and may be

used with it. Note that ATL master mode signaling is not compatible with the current standard 64K master

mode signaling; therefore, for back to back connections, an ATL unit will only operate at 64K when

connected to another ATL unit. If one interface is an ATL unit and the other is not, back to back operation

must be set to 56K.

ATL CSU/DSU Link Module Information

The ATL CSU/DSU link module is normally configured to receive clock from the connected network.

When two ATL CSU/DSU link modules are to be used on a leased line in a back-to-back set-up, one of the

modules must provide the clock.

These modules may have either the UP/DOWN switch type or the ON/OFF slide switch type. Each type is

illustrated below.

Figure 3 - 1 Rear View of ATL CSU/DSU Link Module with UP/DOWN Switches

Figure 3 - 2 View of ATL CSU/DSU Link Module with Sliding ON/OFF Switches

When connecting two bridge/routers back-to-back with CSU/DSU link modules, a null-modem cable is

required to crossover the pins on the links. Crossing over the pins allows two bridge/routers both

configured as DTE interfaces to be connected together.

Switch number 1 determines whether the ATL CSU/DSU link module will generate clocks or receive clocks.

When switch 1 is down (on), the normal position, the module receive clocks from the connected network.

When switch 1 is up (up), the module will generate clocks. When a pair of IOLINK Routers are connected

back-to-back with ATL CSU/DSU link modules one module must be set to generate clocks and one module

must be set to receive clocks. On 64 Kbps units only, switch number 3 determines the mode of the ATL

CSU/DSU. When switch 3 is down (on), the CSU/DSU is in DDS (Digital Data Service) mode for normal

connection to the 64 Kbps digital service. When switch 3 is up (off), the CSU/DSU is in LDM (Limited

Distance Modem) mode for back-to-back connection with a null-modem cable.

On 56 Kbps units, the position of switch 3 is not a factor for back-to-back connection with a null-modem

cable. Switch 1 must still be set as noted above.

A DSU/CSU crossover cable would be constructed as follows:

1 --> 7

2 --> 8

7 --> 1

8 --> 2