Event Logs

A.10

— IOLINK-PRO & 520 Reference Manual

* Closing remote site X (no NCPs open)

Generated when no Network Control Protocols operating.

* Closing remote site X (nonexistant)

Generated when remote site being deleted by the operator.

* Closing remote site X (not enabled)

Generated when remote site autocall being disabled by the operator.

* Closing remote site X (PVC change)

Generated due to the enabling or disabling of PPP encapsulation over frame relay.

* Closing remote site X (resumption failure)

Generated due to failure to resume a suspended connection.

* Closing remote site X (scheduled down)

Generated due to time-of-day schedule deactivation of the connection.

* Closing remote site X (suspension timeout)

Generated due to reaching maximum time that the connection may be suspended.

* Closing remote site X (usage limit)

Generated due to reaching usage limit for this 24 hour period.

* Config. erase failed

Generated when, during a software update, the device configuration is not erased from the non-volatile

memory within the time limit. Possible hardware failt.

* Configuration saved

Generated when the save configuration option has been activated.

* Configuration too large to be saved

Generated when the bridge/router attempts to save a configuration that does not fit in the reserved area of

non-volatile RAM.

* Connection to LAN X failed, trying ...

Generated when failure of the LAN interface external loopback test is detected.

*Count overflow. Reset to history size.

Generated when the number of events since the event log was cleared exceeds the counter capacity (32,768). Event

numbers will start over again from 1.

* DHCP server – out of addresses in IP pool

Generated when the last address from the DHCP IP Address pool has been assigned to a device.