Event Logs

IOLINK-PRO & 520 Reference Manual —

A.11

* Download aborted – Incomplete file

Generated when a TFTP download is abortet before the file transfer is complete

* Download aborted – Invalid FCS

Generated when there is a checksum failure after a file download.

* Download aborted – Incompatible boot code

Generated when the operating code file downloaded is incopatible with the boot code in this device. The updated

boot code software must be loaded before the operating code can be updated.

* Download aborted – Incompatible software

Generated when the software downloaded is incompatible with this device

* Download configuration too large

The configuration file that is being downloaded will not fit in the memory of this router

* E-mail server added to firewall

The IP address of the E-mail server added to the table of services available through the firewall.

* E-mail server removed from firewall

The IP address of the E-mail server removed from the table of services available through the firewall.

* Erasing config. block: starting

Generated as a notification that the configuration of this device is being erased from non-volatile memory prior to

loading a software update.

* Error loading configuration

Generated during a warm start when an error is detected while restoring a configuration from non-volatile

RAM.

* Feature upgrade failure, try again

Generated when the device detects a checksum error for the feature upgrade block.

* File copy failed: file crc: X, verify crc: X

Generated when performing a code upgrade and the calculated CRC was found to be different from the

transferred CRC (flash.fcs) value.