3.8

— IOLINK-PRO & 520 Reference Manual

V.35 Link Pinouts

13

1

25

14

DB25 Female DTE

DB25

Contact

Number

M.34

Contact

Number

CCITT

Circuit

Number

Circuit

Name

Direction

To From

DCE DCE

1

A

Protective Ground

NA

2

----------

3

----------

4

C

105

Request to Send

X

5

----------

6

E

107

Data Set Ready

X

7

B

102

Signal Ground

NA

8

F

109

Data Channel Received Line Signal Detector

X

9

P

103

Transmitted Data (A)

X

10

S

103

Transmitted Data (B)

X

11

R

104

Received Data (A)

X

12

T

104

Received Data (B)

X

13

----------

14

V

115

Receiver Signal Element Timing (A)

X

15

----------

16

X

115

Receiver Signal Element Timing (B)

X

17

----------

18

U

113

Transmitter Signal Element Timing (A) DTE

X

19

W

113

Transmitter Signal Element Timing (B) DTE

X

20

H

108.2

Data Terminal Ready

X

21

141

Local Loopback

X

22

J

125

Calling Indicator

X

23

Y

114

Transmitter Signal Element Timing (A)

X

24

----------

25

a

114

Transmitter Signal Element Timing (B)

X

Figure 3 - 10 V.35 Link Pin Outs

The connecting cable must be a shielded cable.

Circuits which are paired (contain an (A) and (B) reference) should be connected to twisted pairs

within the connecting cable.

NOTE For U.K. Approval:

The connecting cable should be manufactured from Belden Cable, or a cable with equivalent specifications.

One end must be terminated in a male 34 pin X.21 bis connector as defined in ISO-2593 1984. The other

end must be terminated in a male 25 pin X.21 bis connector as defined in ISO-2110 1989. The cable may be

any length between 0 and 5M.

Advertising