HO W DO I …

CONNECT STANDARD CONTROL CIRCUITS?

If you are using an output contactor or dynamic

braking, go to page 19.


The table on the opposite page lists the functions of

the Model 1000AR. The table lists the connections and
descriptions of the control circuits. Read the descriptions of
the operations of these circuits very carefully. There are
differences between analog and digital modes.


The control circuits of Model 1000AR motor control

operate on 48 VDC. This results from using the positive and
negative 24 VDC supplies. Using 48VDC helps balance the
load of relays and other devices on the power supplies.


The maximum current from each of the raw supplies is

50 milliamps. Due to this limitation, you must use an
external supply when you use several external relays.

THE POWER SUPPLIES OF THE MODEL 1000AR

SHOULD NOT BE USED FOR EXTERNAL EQUIPMENT!
Powertec has an optional power supply (part # 127-101)
available for 24VDC to power external circuits.


It is possible to operate control circuits with a variety of

devices. Standard operator devices are O.K.., but the
current flow to these devices is very small. When locating
pushbuttons more than 30 feet away from the motor control,
consider using 120 VAC control circuits.

Install ESTOP buttons Do NOT place a jumper across the Emergency Stop terminals. Because the

drive has a ramp to stop capability, this could set up an UNSAFE situation. IT IS STRONGLY
RECOMMENDED THAT AN EMERGENCY STOP BUTTON (or an ESTOP relay) BE CONNECTED TO
THE DRIVE! This should be of the MAINTAINED CONTACT TYPE.

T he motor thermal must be used to PROPERLY protect the motor!

You can use a "two-wire" control by connecting a contact or switch between terminals 11 and 13 on

TB2. Leave off the RAMP STOP and START buttons. This DOES NOT disable the RAMP STOP function.
The only way to disable the RAMP STOP function is removing the RAMP STOP jumper.

The RAMP STOP function in the analog mode shorts the analog reference input to zero. This causes

the motor to decelerate to zero speed before shut-down.


Note that the JOG function is disabled by the RUN function. If you activate the JOG input while the

RUN mode is in operation, there will be no effect.


The HOLD function zeroes the speed reference to bring the motor to a stop and holds the drive at

zero speed. THE DRIVE IS NOT OFF IN THE HOLD MODE! There is a potential for the motor to run, so
the appropriate safety precautions should be taken.

RAMP

STOP

TO

MOTOR

THERMAL

TB2

16

15

14

13

12

11

10

9

8

START

JOG

RUN HOLD

Bus Loader

Interlock

EMER

STOP

R+ R-

7

3

2

1

TB5