Page 2 – PowerTec Regenerative Brushless DC Motor Control 1000AR User Manual

Page 48

Advertising
background image

Model

1000AR

Installation and Operation Manual

P

AGE

47


OFFICIAL 6/4/2001

POWERTEC Model 1000AR Drive Start Up and Troubleshooting Chart

NOTE: This chart assumes standard control connections

and no options installed which affect speed control.

CC = Current Controller board.

Is

BUS LED

GREEN

?

To

Page 3

Wait up to 30 seconds for

BUS LED to change from

RED to GREEN

From

Page 1

No

Is

BUS LED

RED

?

No

Replace Current

Controller board

No

Disconnect Motor

Measure the Bus
Voltage between

POSITIVE BUS Tab

and the NEGATIVE

BUS Tab on the

Capacitor Board.

Is

Bus

VDC

< 10%

?

No

Is

Charge

Fuse OK

?

Line VAC = 230
Bus VDC = 320

Line VAC = 380
Bus VDC = 530

Line VAC = 460
Bus VDC = 640

Yes

Turn Power Off

Remove FU1 on
Capacitor Board

No

Replace

Charge Fuse

Replace

Capacitor Board

Yes

Bus

Loader

Connected

?

Disconnect

Bus Loader and

Start Over.

No

Yes

Is

Bus

VDC

> 90%

?

Yes

No

Replace

Transistor

Module

Turn Power Off

Perform Diode

Bridge Test

Is

Diode

Bridge OK

?

Yes

No

Replace Diode

Bridge

Turn Power Off

Check Choke L1

for continuity

Is

Choke

OK

?

Perform

Transistor Module

Leakage Test

Is

Transistor

Module

OK?

Yes

No

Replace

Choke

No

Replace

Capacitor Board

Yes

Is

Line

Voltage

Too Low

?

Yes

Yes

Fix Line Voltage

Problem

Replace

Capacitor Board

Nominal Line Voltage = 230VAC

Too Low < 208 VAC

Nominal Line Voltage = 380VAC

Too Low < 342VAC

Nominal Line Voltage = 460VAC

Too Low < 415VAC

Page 2

Yes

Advertising