1000ar, Page 6 – PowerTec Regenerative Brushless DC Motor Control 1000AR User Manual

Page 56

Advertising
background image

Model

1000AR

Installation and Operation Manual

P

AGE

55


OFFICIAL 6/4/2001

POWERTEC Model 1000AR Drive Start Up and Troubleshooting Chart

NOTE: This chart assumes standard control connections

and no options installed which affect speed control.

CC = Current Controller board.

Is

motor at

50% speed

?

Put Motor
In Service

From

Page 5

Page 6

Is

PHAD

LED

On ?

Yes

Increase

SPEED

reference
from 10%

to 50%. If

CURREN

T LIMIT is

turned

down, turn

it up to

50% CW.

No

Is

CURRENT

LIMIT LED

On ?

Yes

+5VDC

TB2-5(+)

TB2-16(-)

?

Correct

Speed

Reference

No

Adjust

MAX pot

on Speed
Controller

board

Is

motor at

50% speed

?

Is

motor

running faster

than 50%

?

Disconnect

load from the

motor and

start over

No

Yes

50% speed refers to 1/2 of

the max speed of the motor.

Is

the load

connected to

the motor

?

Is

speed at

base speed

or more

?

Yes

No

Yes

No

Are

all of the

Driver board

LED's OK

?

Turn off power,

disconnect T1, T2,

T3. Turn on power

and rotate motor

by hand.

Yes

No

Replace

Base Driver

Board

2nd

Replace

Current

Controller

board

1st

Turn off power,

reconnect T1, T2,

and T3. Replace

Speed Controller

board. Restart.

Is

Speed

at 50%

?

Yes

No

Replace

Motor

Return to

Start

Is

motor an
F2 motor

?

No

Yes

Remove

Phase

Advance

Chip U8 on

CCB

Replace

Speed

Controller

board

No

Replace

Capacitor

Board

Yes

Yes

No

Yes

No